- Overview
- Availablity
- Technical Specifications
- Application Gallery
- Download Center
![]() |
Overview
Dynaglas offers high durability, high light transmission and weather resistance. It is ideal for greenhouse coverings and skylight applications. Professionals favor Dynaglas for noncorrosive industrial structural roofing and siding (cladding), while homeowners favored Dynaglas for a multitude of DIY projects. Dynaglas is available in a wide variety of colors and profiles,
Typical Applications
|
- ????
| Availability | |
| Product Name | Dynaglas Plus, Dynaglas Solar Soft |
| Profile | |
| Standard Length | Up to 48 ft |
| Standard Width | 49.6" (73.6” width special order) |
| Thickness | .03” (0.8mm) |
| Standard colors | Clear, Opal (white), Grey, Diffused |
Light Transmission Characteristics
DynaGlas offers the same sparkling clarity as glass. But because DynaGlas requires no shade casting glazing system, DynaGlas transmits as much as 7% more light than glass. DynaGlas Plus SolarSoft 85™ offers high light transmission (85%), but also offers 100% light diffusion, helping to spread light throughout the greenhouse and reduce shadows.

Technical Specifications
| Dimensions | Value (English (Metric)) | ||
| Panel Widths (gross) 49.6" or |
73.6" (1260 mm or 1870 mm) | ||
| Panel Widths (net after one corrugation overlap) | 47.8" (±4 ft) or 71.8" (±6 ft) (1216 mm or 1824 mm) | ||
| Panel Lengths (custom cut to specification) | 3' to 38' (914 mm to 11580 mm) | ||
| Corrugation/Wave Depth | Greca 0.625" (16 mm) | Omega .591" (15mm) | ||
| Corrugation/Wave Pitch | 2.99" (76 mm) | ||
| Weight | Greca .24 lbs./sf (1220 g/m2) | Omega Greca .23 lbs./sf (1104 g/m2) | ||
| Thickness | 0.03" (0.8 mm) | ||
| Number of Corrugations/Waves | 17 (49.6” panel) or 25 (73.6” panel) |
||
| Thermal | Value (English (Metric)) | Test Method | |
| Optimal Service Temperature Range |
- 40° F to +212° F (- 40° C to + 100° C) | ||
| Maximum Service Temperature | 270° F (132° C) | ||
| Minimum Service Temperature | - 103° F (- 75 ° C) |
||
| Heat Deflection Temperature Load, 275° F (psi) | 275 | ASTM D-648 | |
R / U-Factor and K-Value |
R = .83 / U 1.20 = (K = 5.8 W/m2 K) | ||
| Coefficient of Linear Thermal Expansion | 3.6 x 10 -5 in./in./°F (6.5 x 10 -5 cm/cm/°C) | ASTM D-696 | |
| Thermal Conductivity BTU/lb. (F°) | 1.4 | ASTM C-177 | |
| Mechanical | |||
| Tensile Strength at Yield, 2 in./min. (psi) | 9,000 | ASTM D-638 | |
| Tensile Strength at Break, 2 in./min. (psi) | 9,500 | ASTM D-638 | |
| Elongation at Yield, 2 in./min. (%) | > 6 % | ASTM D-638 | |
| Elongation at Break, 2 in./min. (%) | > 80 % | ASTM D-638 | |
| Tensile Modulus, 0.04 in./min. (psi) | 340,000 | ASTM D-638 | |
| Flexural Modulus 0.052 in./min. (psi) | 310,000 | ASTM D-790 | |
| Flexural Strength at Yield, 0.052 in./min. (psi) | 13,500 | ASTM D-790 | |
| Shear Strength (psi) | 6,180 | Factory Test | |
| Izod Impact Strength, Notched (73° F), ft./lb./in. | 18 | ASTM D-256 | |
| Rockwell Hardness, R Scale | 118 | ASTM D-785 | |
| Impact Resistance (falling dart) | 444 in. lbs. (50 joules) | ISO 6603/1 | |
| OSHA point-29 | Passed 200 lb. | CFR 1910.23 (e) (8) | |
| Uplift | Passed UL 90 | UL 580 | |
| Longitudinal Bending Radius | 16' (4.9 m) recommended; 13’ (4 m) min. | ||
| Optical | |||
| Light Transmission/Diffusion | Light Transmission | Diffusion | |
| Clear (DynaGlas Plus) | 92 % | >1% | ASTM D-1003 |
| LDT | 90.5% | 10% | ASTM D-1003 |
| SolarSoft 90™ | 90% | 40% | ASTM D-1003 |
| SolarSoft 85™ | 85% | 100% | ASTM D-1003 |
| Translucent White | 42% | 100% | ASTM D-1003 |
| Transparent Gray | 35% | 10% | ASTM D-1003 |
| UV Light Transmission (all products) | < 1 % | ||
| UV Protection (co-extruded; not laquer or laminate) | DG SE & Plus, 1 side; DG UV2™ both sides | Factory Test | |
| Yellowness Index | < 1 | ASTM D-1925 | |
| Solar Heat Gain, ft.2 (BTU/hr.) | |||
| Clear |
218 | ||
| Clear LDT | 215 | ||
| White-Opal | 128 | ||
| Gray | 120 | ||
| Other | |||
| Flammability Rating | CC2 (CC1 available if required) | ASTM D-635-91 | |
| Self Ignition | 1030° F (554° C) | UBC Standard 52-3 | |
| Flash Ignition | 840° F (449° C) | UBC Standard 52-3 | |
| Smoke Density (%) | 51 | ASTM D-2843 | |
| Smoke Developed | 47.0 | UL 723 (ASTM E-84) | |
| Flame Spread | 4.7 (Class A | UL 723 (ASTM E-84) | |
| Condensation Control | Built-in; proprietary (10-year warranty) | Factory Test | |
| Tolerances | |||
| Thickness |
0.030" to 0.032" (0.77 mm to 0.83 mm) | Factory Test | |
| Length | 0 to + 0.5" (0 to +15 mm) | Factory Test | |
| Width | ± .4" (± 10 mm) | Factory Test | |
| Visual Defects (inclusions, bubbles, black specks, gel, etc.) | If defect is not visible by inspection from a distance of 1 meter, it is not considered to be a defect. Surface abrasion may occur in transit. This is not considered a defect as DynaGlas is not intended for “architectural optical clarity” applications. This type of abrasion will not affect durability. |
||
| Literature | |
| DynaGlas Plus | |
| Installation Guides | |
| DynaGlas Plus Installation Guide (U.S. English) | |
| Warranties | |
| DynaGlas Warranty (U.S. English) | |